#################### PYOTE 5.7.11  session started: Fri Oct  3 16:18:27 2025  ####################

filename: C:/Users/Stefan/Pictures/2025/2025-10-02 Sternbed/1/lc-21.csv

==================== file header lines ====================
# PyMovie Version 4.1.5
# source: C:\Users\Stefan\Pictures\2025\2025-10-02 Sternbed\1\20251003_023652_816x620_G24dB_0100ms.adv
#
# Aperture photometry was used to extract the lightcurves
#
# lunar background: False
# yellow mask = default: False
#
# aperture name: target
# ____ aperture size: 21
# ____ x,y: (421, 337) at frame 299
# ____ threshold: 130
# ____ def mask radius: 4.0
# ____ color: green
# ____ joggable: False
# ____ auto textOut: False
# ____ thumbnail source: False
# ____ csv output order: 0
#
# aperture name: track
# ____ aperture size: 21
# ____ x,y: (225, 314) at frame 299
# ____ threshold: 850
# ____ def mask radius: 4.0
# ____ color: yellow
# ____ joggable: False
# ____ auto textOut: False
# ____ thumbnail source: False
# ____ csv output order: 1
#
# aperture name: ref
# ____ aperture size: 21
# ____ x,y: (268, 344) at frame 299
# ____ threshold: 305
# ____ def mask radius: 4.0
# ____ color: green
# ____ joggable: True
# ____ auto textOut: False
# ____ thumbnail source: False
# ____ csv output order: 2
#
# date at frame 0: 2025-10-03
#ACQUISITION-DELAY: 0.0
#ALTITUDE: 557.2
#AUTHOR: Stefan Meister
#BINNING-X: 2
#BINNING-Y: 2
#CAMERA-DRIVER-NAME: UVC
#CAMERA-FIRMWARE-VERSION: 1.3.3
#CAMERA-MODEL: DVTI+CAM
#CAMERA-SENSOR-INFO: Sony IMX430LLJ-C (9.2mm 1624x1240 4.5um CIS)
#CAMERA-SERIAL-NO: 17
#CAMERA-VENDOR-NAME: DVTI
#COMMENT: 
#HEIGHT: 620
#INSTRUMENT: DVTI+CAM #17 FW 1.3.3, Sensor IMX430
#LATITUDE: 47.5195612
#LONGITUDE: 8.5706731
#OBJNAME: (43266) 2000 DZ83 occ. UCAC4 554-017029
#OBSERVER: Stefan Meister
#RECORDER-SOFTWARE: DvtiCamControl
#RECORDER-SOFTWARE-VERSION: 5.9.0-81
#TELESCOPE: Newton 2.5m
#WIDTH: 816
#
# Aperture photometry was used to extract the lightcurves
==================== end header lines ====================

No time step irregularities found.

timeDelta: 0.0999933 seconds per reading
timestamp error rate: 0.00%

signal-ref is selected as the reference curve for normalization.

signal-target is the target curve.

signal-target is the target curve.

signal-target is the target curve.

Use min/max event to locate a "D and R" event has been selected

minEvent: 2  maxEvent: 2

Number of candidate solutions: 297 (using event min/max entries)

New solver results...

Integer (non-subframe) solution...
B:3939.78  A:877.33
in entryNum units: D: 128  R: 130

noise corr coefs: [1.00, 0.0639]  (based on 298 points)  sigmaB: 1008.63

noise corr coefs: [1.00, 0.0639]  (based on 298 points)  sigmaB: 1008.63

Subframe adjusted solution...
B:3939.78  A:877.33
in entryNum units: D: 128  R: 130  D(subframe): 128.0000  R(subframe): 130.0000

in frameNum units: D: 128  R: 130  D(subframe): 128.0000  R(subframe): 130.0000

... end New solver results

signal-target is the target curve.

Calculating the noise-induced-drop probability - this can take many seconds!  Be patient.

Error bar report based on 50,000 simulations (units are readings)...

loDbar   @ .68 ci:  -0.1586
hiDbar   @ .68 ci:   0.1753
loDbar   @ .95 ci:  -0.4683
hiDbar   @ .95 ci:   0.3674
loDbar   @ .9973 ci:  -0.9290
hiDbar   @ .9973 ci:   0.6800

loDurBar @ .68 ci:  -0.2566
hiDurBar @ .68 ci:   0.2601
loDurBar @ .95 ci:  -0.5906
hiDurBar @ .95 ci:   0.5859
loDurBar @ .9973 ci:  -1.1171
hiDurBar @ .9973 ci:   0.9804

Timestamp validity check ...

From timestamps at D and R, calculated 2 reading blocks.  From reading blocks, calculated 2 blocks.

Timestamps appear valid @ D and R

================= 0.68 containment interval report =================

B: 3939.78  {+/- 58.53}  sigmaB: 1008.63

A: 877.33  {+/- 103.74}  sigmaA: 103.74

magDrop report: percentDrop: 77.7  magDrop: 1.631  +/- 0.129  (0.68 ci)

DNR: 3.04

D: 128.00 {+0.18,-0.16} (frame number)
D: [02:37:05.5880]  {+0.0175,-0.0159} seconds

R: 130.00 {+0.16,-0.18} (frame number)
R: [02:37:05.7880]  {+0.0159,-0.0175} seconds

Duration (R - D): 2.0000 {+0.2584,-0.2584} readings
Duration (R - D): 0.2000 {+0.0258,-0.0258} seconds

=============== end 0.68 containment interval report ===============

================= 0.95 containment interval report =================

B: 3939.78  {+/- 117.05}  sigmaB: 1008.63

A: 877.33  {+/- 207.48}  sigmaA: 103.74

magDrop report: percentDrop: 77.7  magDrop: 1.631  +/- 0.259  (0.95 ci)

DNR: 3.04

D: 128.00 {+0.37,-0.47} (frame number)
D: [02:37:05.5880]  {+0.0367,-0.0468} seconds

R: 130.00 {+0.47,-0.37} (frame number)
R: [02:37:05.7880]  {+0.0468,-0.0367} seconds

Duration (R - D): 2.0000 {+0.5883,-0.5883} readings
Duration (R - D): 0.2000 {+0.0588,-0.0588} seconds

=============== end 0.95 containment interval report ===============

================= 0.9973 containment interval report ===============

B: 3939.78  {+/- 175.58}  sigmaB: 1008.63

A: 877.33  {+/- 311.22}  sigmaA: 103.74

magDrop report: percentDrop: 77.7  magDrop: 1.631  +/- 0.388  (0.9973 ci)

DNR: 3.04

D: 128.00 {+0.68,-0.93} (frame number)
D: [02:37:05.5880]  {+0.0680,-0.0929} seconds

R: 130.00 {+0.93,-0.68} (frame number)
R: [02:37:05.7880]  {+0.0929,-0.0680} seconds

Duration (R - D): 2.0000 {+1.0487,-1.0487} readings
Duration (R - D): 0.2000 {+0.1049,-0.1049} seconds

=============== end 0.9973 containment interval report =============

D frame number: 128.00
D: 0.6800 containment intervals:  {+/- 0.18} (readings)
D: 0.9500 containment intervals:  {+/- 0.47} (readings)
D: 0.9973 containment intervals:  {+/- 0.93} (readings)

R frame number: 130.00
R: 0.6800 containment intervals:  {+/- 0.18} (readings)
R: 0.9500 containment intervals:  {+/- 0.47} (readings)
R: 0.9973 containment intervals:  {+/- 0.93} (readings)

Duration (R - D): 2.0000 readings
Duration: 0.6800 containment intervals:  {+/- 0.2584} (readings)
Duration: 0.9500 containment intervals:  {+/- 0.5883} (readings)
Duration: 0.9973 containment intervals:  {+/- 1.0487} (readings)

=============== Summary report for Excel file =====================

This light curve has not been block integrated.

This light curve has been normalized against a reference star.
... signal-ref was used for normalization with X offset: 0
... 12 readings were used for smoothing



The observed drop has a less than 3 sigma probability level of being a noise-induced-event

All times are calculated/reported based on the assumption that timestamps are start-of-exposure times.

It is critical that you make appropriate time adjustments when timestamps are NOT start-of-exposure times.
If you use the North American Excel Spreadsheet report, all times will be properly corrected
for camera delay and reported start-of-exposure times.
For other users worldwide, use the appropriate corrections documented in the North American Spreadsheet report form - use
the documentation shown on the Corrections Tables tab.

magDrop report: percentDrop: 77.7  magDrop: 1.631  +/- 0.259  (0.95 ci)

DNR: 3.04

D time: [02:37:05.5880]
D: 0.6800 containment intervals:  {+/- 0.0175} seconds
D: 0.9500 containment intervals:  {+/- 0.0468} seconds
D: 0.9973 containment intervals:  {+/- 0.0929} seconds

R time: [02:37:05.7880]
R: 0.6800 containment intervals:  {+/- 0.0175} seconds
R: 0.9500 containment intervals:  {+/- 0.0468} seconds
R: 0.9973 containment intervals:  {+/- 0.0929} seconds

Duration (R - D): 0.2000 seconds
Duration: 0.6800 containment intervals:  {+/- 0.0258} seconds
Duration: 0.9500 containment intervals:  {+/- 0.0588} seconds
Duration: 0.9973 containment intervals:  {+/- 0.1049} seconds

Enter D and R error bars for each containment interval in Excel spreadsheet without + or - sign (assumed to be +/-)

=========== end Summary report for Excel file =====================

Solution 'envelope' in the main plot drawn using 0.95 containment interval error bars

fit metrics for signal-target

fit metrics === noiseSigmaDistance: 10.0

fit metrics === time error bar: +/- 0.0468 seconds

fit metrics === DNR: 3.04  
fit metrics === B: 3939.78  A: 877.33 sigmaB: 1008.63  sigmaA: 103.74
fit metrics === magDrop report: percentDrop: 77.7  magDrop: 1.631  +/- 0.259  (0.95 ci)

fit metrics === D frame number: 128.0000

fit metrics === R frame number: 130.0000

fit metrics === duration: 0.2000 seconds

fit metrics === D time: [02:37:05.5880]

fit metrics === R time: [02:37:05.7880]




signal-target is the target curve.



#################### Session ended: Fri Oct  3 16:29:11 2025  ####################